Nadeau S, Kovacs S, Gravel D, Piotte F, Moffet H, Gagnon D, Hébert LJ. Interobserver reproducibility of the visual estimation of range of motion of the shoulder. Terwee CB, deWinter AF, Scholten RJ, Jans MP, Devillé W, van Schaardenburg D, Bouter LM. Inter-observer reproducibility of measurements of range of motion in patients with shoulder pain using a digital inclinometer. Ann Rheum Dis 2002 61:115–120.ĭe Winter AF, Heemskerk MA, Terwee CB, Jans MP, Devillé W, van Schaardenburg DJ, et al. Measurement of three dimensional shoulder movement patterns with an electromagnetic tracking device in patients with a frozen shoulder. Vermeulen HM, Stokdijk M, Eilers PH, Meskers CG, Rozing PM, Vliet Vlieland TP. Dynamic measurements of three-dimensional scapular kinematics: a validation study. Karduna AR, McClure PW, Michener LA, Sennett B. Review of goniometry emphasizing reliability and validity. Evaluating change in clinical status: reliability and measures of agreement for the assessment of glenohumeral range of motion. Measuring shoulder internal rotation range of motion: a comparison of 3 techniques. A study on human upper-limb muscles activities during daily upper-limb motions. This study showed highly reliable shoulder joint ROM measurements in healthy adults using the Kinovea software. The inter-rater reliability ranged from an intraclass correlation coefficient value of 0.95 to 0.98, whereas the intrarater reliability ranged from an intraclass correlation coefficient value of 0.98 to 0.99. Shoulder flexion, abduction, and external and internal rotation ROM were measured with the patient in supine position.
![download kinovea download kinovea](https://crack4windows.com/thumbnail?path=%2Fcontent%2Fimages%2Fscreens%2Fkinovea_5.png)
Intrarater reliability was examined by a single rater within the same day.
![download kinovea download kinovea](https://ars.els-cdn.com/content/image/1-s2.0-S0031938420304583-gr2.jpg)
Shoulder joint ROM was measured in 52 healthy individuals (mean±SD age was 26.7±4.2 years) using Kinovea photographic measurements by three trained raters.
#Download kinovea software
This study was conducted to investigate the inter-rater and intrarater reliability of Kinovea software for measuring shoulder joint ROM in healthy individuals. However, the software’s reliability in measuring shoulder joint ROM has not been studied. Kinovea software is a recent video-based method that uses a virtual goniometer to obtain values for the ROM of joints. With modern innovations in technology, new methods other than the universal goniometer have been applied. Goniometry is a tool used frequently for measuring and documenting range of motion (ROM) during a physical therapy examination.